Waste Bunker and Tipping Floor Fires: Where an Automated Water Cannon Fits

Posted On: 

November 21, 2026 

| Category: 

A waste bunker, a tipping floor or an outdoor pile is the hardest kind of space to protect from fire. It is too large for a sprinkler head to cover and too far from a crew with a hose to reach in time. Fires in open areas start small and grow fast, and in a recycling facility the fuel is already stacked and waiting.

Why open areas are the gap

Recycling plants already know their machinery is a fire source. Friction, bearing failures and foreign objects in shredders can ignite material, and discarded lithium-ion batteries have become a growing cause of fires in waste facilities. Spark detection at the shredder and conveyor catches many of these early. But a fire that starts in the open, or that escapes the machine, lands in a space where sprinklers were never designed to work: high ceilings, large floor areas and material piles that change shape every day.

What an automated water cannon does

The Firefly Automated Water Cannon fills that gap with fully automatic, targeted suppression. Flame detectors watch each zone around the clock. When a fire is detected, the cannon aims itself, opens its valve and puts high-flow water on the fire area, then returns to its park position and stands ready. No operator has to be present, awake or nearby.

  • The area is divided into zones, and each zone is covered by flame detectors that monitor continuously, day and night, manned or unmanned.
  • Detection triggers the alarm, and the cannon begins aiming at the fire area.
  • The valve opens and high-flow water is applied where the fire is. Once it is out, the cannon keeps spraying for a safety margin, then parks and stays ready.

Suppression can start in as little as 10 seconds from detection, and typically in under 15. In a fast-growing fire, those seconds are the difference between a wet floor and a lost building.

Water, not foam

Water is the primary extinguishing agent because it needs no chemical additives and, according to Firefly, requires no collection or special disposal after an activation. That matters most in recycling facilities, where residue management is already a concern. The cannon can also be programmed to wet the surrounding area first to contain and stabilize the fire, then target the core once control is established, so a high-pressure jet does not scatter burning material.

Two sizes, one system

The cannon comes in two sizes, DN50 (2 inch) and DN80 (3 inch), with motorized 360 degree rotation and 180 degree tilt. The DN50 delivers 925 L/min (about 244 US gpm) at 5 bar with a reach of 30 m (about 98 ft). The DN80 delivers 3,250 L/min (about 859 US gpm) at 5 bar with a reach of 45 m (about 148 ft). Hydraulic design for a specific site is engineered per project. See the full specifications.

Part of a complete Firefly system

The cannon runs on the same Firefly EXIMIO platform as the spark detection and quick suppression systems RDi designs and services, so it can be added to an existing Firefly installation or built into a new one. For the shredder and conveyor side of the plant, see RDi’s recycling solutions.

Common questions

Why are open areas the gap in fire protection?

A fire that starts in the open, or that escapes the machine, lands in a space where sprinklers were never designed to work: high ceilings, large floor areas and material piles that change shape every day.

What does an automated water cannon do?

Flame detectors watch each zone around the clock. When a fire is detected, the cannon aims itself, opens its valve and puts high-flow water on the fire area, then returns to its park position and stands ready. No operator has to be present, awake or nearby.

How fast does it start?

Suppression can start in as little as 10 seconds from detection, and typically in under 15.

Why water instead of foam?

Water is the primary extinguishing agent because it needs no chemical additives and, according to Firefly, requires no collection or special disposal after an activation.

What sizes does the cannon come in?

The cannon comes in two sizes, DN50 (2 inch) and DN80 (3 inch). The DN50 delivers 925 L/min at 5 bar with a reach of 30 m. The DN80 delivers 3,250 L/min at 5 bar with a reach of 45 m.

Have a question about your own process? Ask an engineer below, or call 507.587.8086.

Ask an Engineer

Have a question about fire prevention or detection at your facility? We reply personally, usually within 72 hours.